More items from this sellerView All

EZD160S3100N Spot Schneider plastic case circuit breaker EZD160 100A

0 reviews

Spot Schneider plastic case circuit breaker EZD160S3100N EZD160 100A  EZD molded case circuit breaker Model Number: EZD160S3100N

Description

PRODUCT INFORMATION OF SCHNEIDER Spot plastic case circuit breaker EZD160S3100N EZD160 100A

 

main information

Product Series EZD
product type Breaker
product short name EZD160S
circuit breaker application Distribution Protection
number of poles 3P
Description of protection pole 3D
Leakage current protection No leakage protection
Rated current [In] 100 A at 40 °C
Circuit breaker model S
Network Type AC
Network frequency 50/60Hz
control type Handle
installation type Fixed
installation method Chassis mount
Connection method – top Front connection
Connection method – lower end Front connection
Rated insulation voltage [Ui] 690 V conforming to EN/IEC 60947-2
Rated impulse withstand voltage [Uimp] 6 kV conforming to EN/IEC 60947-2
Rated working voltage [Ue] 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity 50 kA Icu at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
100 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 500 V AC 50/60 Hz conforming to EN/ IEC 60947-2
use category AC class
Use breaking capacity [Ics] 18 kA at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA at 220/230 V AC 50/ 60 Hz conforming to EN/IEC 60947-2
25 kA at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2
5 kA at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical life 10000 times
Electrical life 5000 cycles 440 V In conforming to EN/IEC 60947-2
Phase spacing 35 mm
Trip unit name TM-D
Trip unit type Thermomagnetic
Release rating 100 A at 40 °C
protection type Overload protection (thermal protection)
short circuit protection (magnetic protection)
Long time delay current setting type Fixed
Long delay current setting value [Ir] 1 In
Instantaneous protection current setting type Fixed
Short circuit instantaneous protection 1000 kA
high 165 mm
width 105 mm
depth 68 mm
Product Weight 1.6kg
model EZD160
Standards compliant IEC 60947-2
EN 60947-2
pollution level 3 Conforming to IEC 60947-1
operating temperature -25…70°C
storage environment temperature -50…85 °C
Warranty 18 months

0.0 Average Rating Rated (0 Reviews)

Rated
0%
Rated
0%
Rated
0%
Rated
0%
Rated
0%

Be the first to review “EZD160S3100N Spot Schneider plastic case circuit breaker EZD160 100A”

Your email address will not be published. Required fields are marked *