Schneider A9F18104 micro-break IC65N 1P C4A single-stage air switch circuit breaker

0 reviews

Schneider A9F18104 micro-break IC65N 1P C4A single-stage air switch circuit breaker A9 miniature circuit breaker Model Number: iC65N-C4A/1P

Description

PRODUCT INFORMATION OF SCHNEIDER A9F18104 micro-break IC65N 1P C4A single-stage air switch circuit breaker

 

main information

Product Series Acti 9
Product Series Acti 9
product name IC65
product type Miniature Circuit Breaker
product short name IC65N
number of poles 1P
Applications Distribution protection
Number of guard poles 1
Rated current [In] 4 A at 30 °C
Network Type AC
Trip unit type Thermomagnetic
Trip curve of Schneider A9F18104 micro-break IC65N C
Breaking capacity 50 kA Icu at 12…60 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 100…133 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1
use category AC class conforms to IEC 60947-2
isolation function Applies to IEC 60947-2
Network frequency 50/60Hz
Rated working voltage [Ue] 230/400V AC 50/60Hz
Magnetic trip limit 5…10 x In
current limiting level 3 Conforming to IEC 60898-1
Rated insulation voltage [Ui] 500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947-2
Contact position indication Have
control type  of Schneider A9F18104 micro-break IC65N Handle
local signal indication On/off indicator
installation type Locking clip lock
installation method DIN rail mounting
Width (multiples of 9mm) 2
high of Schneider A9F18104 micro-break IC65N 94 mm
depth of Schneider A9F18104 micro-break IC65N 78.5mm
Product Weight 125g
Mechanical life 20000 times
Electrical life 10000 times
Wiring capacity Tunnel terminal top or bottom 1…25 mm² Solid wire without wire terminal
Tunnel terminal top or bottom 1…16 mm² flexible wire (optional) with or without wire terminal
Stripping length 14 mm power return:
Tightening torque 2.5 Nm power circuit:
Leakage current protection (Required) additional assembly
Standards compliant GB 10963.1
IEC 60898-1
certified product CE
CCS
CCC
IP protection class IP20 conforming to IEC 60529
pollution level 3 Conforming to IEC 60947-2
Moisture resistance 2 Conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
operating temperature -35…70°C
storage environment temperature -40…85°C
Warranty of Schneider A9F18104 micro-break IC65N 18 months