More items from this sellerView All

150-SC2NBD Rockwell AB SMC-50 soft starter current 260A.

0 reviews

150-SC2NBD Rockwell AB SMC-50 soft starter current 260A.Soft Start Series Model No: 150-SC2NBD.SMC-50 Smart Motor Controller, 200…480V, 260 A Line.

Description

PRODUCT INFORMATION OF 150-SC2NBD Rockwell AB SMC-50 soft starter current 260A.

With display No
Voltage type for actuating AC
Rated operating voltage Ue 200 V
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Controller rating 260 A
Continuous duty power structure heat dissipation 780 W
Overload current for line connected devices 87 A
Overload current for delta connected devices 151 A
Controller type SMC-50
Trip classes 5…30
Trip current rating 118% of motor FLC
Base power draw from control module with heat sink fan 75 W @ 24V DC
DV/DT protection RC snubber network
Repetitive peak inverse voltage rating 1400V per UL/CSA/NEMA for power circuit
Operating frequency 47…63 Hz or DC for control power
Rated impulse voltage 6000V per IEC for power circuit
Dielectric withstand 2500V per IEC for power circuit
Line connected motor current Normal/standard duty: 87…260 A @ 400/415/460V AC, 3-phase
Delta connected motor current Normal/standard duty: 151…450 A @ 400/415/460V AC, 3-phase
Transient protection Metal oxide varistors: 220 Joules
Insulation voltage Rated 500V per IEC for power circuit
Line connected motor power Normal/standard duty: 75…200 Hp @ 460V AC, 60 Hz, 3-phase
Delta connected motor power Normal/standard duty: 90…250 kW @ 400/415V AC, 50 Hz, 3-phase
High capacity available fault current, max 65 kA @ 600V, typical current 700 A time delay Class J or Class L fuse for inside delta connected motors
Utilization category MG 1 per UL/CSA/NEMA for normal duty
Option power adder 5VA @ 100…240V AC, 150-SM6 (for each option installed, add to base power to obtain total power requirement)
Standard controller feature Torque control
Standard available fault current, max 30 kA @ 600V, typical current 700 A time delay fuse for inside delta connected motors
Optional controller feature Parameter configuration/programming tools
Integrated motor overload protection Yes
Short circuit protection device performance (SCPD) type Type 1
Control power ride through 22 ms for control power
Control module battery type CR 2032 for control power
Overload type Electronic – using I2t algorithm
Output current, max 300 mA @ 24V DC supply (terminals 8 and 12) for control power

0.0 Average Rating Rated (0 Reviews)

Rated
0%
Rated
0%
Rated
0%
Rated
0%
Rated
0%

Be the first to review “150-SC2NBD Rockwell AB SMC-50 soft starter current 260A.”

Your email address will not be published. Required fields are marked *

You have to login to add images.