More items from this sellerView All

150-F251NBR Rockwell AB SMC Flex soft starter current 251A.

0 reviews

150-F251NBR Rockwell AB SMC Flex soft starter current 251A.Soft Start Series Model No: 150-F251NBR.The 150-F251NBR is an SMC Flex Smart Motor Controller from Allen-Bradley. This motor controller is a Soft-starter device with line Voltage of 200-460VAC, 3-Phase, 50 and 60 Hz and control Voltage of 24 VAC / VDC. This motor controller may be used with line-connected and Delta-connected motors. It is capable of implementing Soft-start, Linear Acceleration/Deceleration, Current Limit, Dual Ramp Start, Full Voltage, Soft Stop, Preset Slow Speed operating modes. With line connected motors, it has an applicable motor current ratings of 84-251 Amperes, power ratings of 75-251 HP @ 60 Hz and 75 -132 kW @ 50 Hz. It is also applicable for use with delta-connected motors with applicable current ratings of 145-435 Amperes, power ratings of 132-250 kW kW @ 50 Hz and 150-350 Hp @ 60 Hz.

Description

PRODUCT INFORMATION OF 150-F251NBR Rockwell AB SMC Flex soft starter current 251A.

Manufacturer Rockwell Automation
Brand Allen-Bradley
Part Number/Catalog No. 150-F251NBR
Manufacturer: Rockwell Automation
Product Line SMC-Flex
Brand: Allen-Bradley
Bulletin Number Solid State Controller
Product Family: SMC Flex Smart Motor Controller
Enclosure Type open
Bulletin Number: 150-F
Controller Rating 251 A, 200 Hp @ 460V AC
Catalog number: 150-F251NBR
Input Line Voltage 200-460V AC, 3-phase, 50 and 60 Hz
Operating Modes: Soft-start, Linear Acceleration/Deceleration, Current Limit, Dual Ramp Start, Full Voltage, Soft Stop, Preset Slow Speed
Control Voltage 24V AC/DC (5-480 A units)
Applicable Motor Type Standard squirrel-cage induction motor or a Wye- Delta, six-lead motor
Rated Voltage 200-460V AC
Line Voltage: 200…460V AC, 3-Phase, 50 and 60 Hz
Control Voltage: 24VAC / 24VDC
Output Current range: Line-Connected Motors: 84-251 Amperes Delta Connected Motors: 145-435 Amperes
Output power range: Line Connected motors: 75-251 HP; 75 -132 kW Delta connected motors: 132-250 kW; 150-350 Hp
Auxiliary Contacts Four (4) Fully-programmable contacts
Human Interface Module Integrated
Communication ports One (1) DPI for optional HMI; One (1) DPI for expansion module
Metering Amps, volts, kW, kWh, MW, MWH, elapsed time, power factor, motor thermal capacity usage
Status Indication Stopped, starting, stopping, at speed, alarm, and fault.
Protection and Diagnostics Power loss, line fault, voltage unbalance, excessive starts/hour, phase reversal, undervoltage, overvoltage, controller temp, stall, jam, open gate, overload, underload, communication fault.

0.0 Average Rating Rated (0 Reviews)

Rated
0%
Rated
0%
Rated
0%
Rated
0%
Rated
0%

Be the first to review “150-F251NBR Rockwell AB SMC Flex soft starter current 251A.”

Your email address will not be published. Required fields are marked *

You have to login to add images.