| Number of outputs, safety related, undelayed, with contact |
2 |
| Number of outputs, safety related, delayed, with contact |
0 |
| Number of outputs, signalling function, undelayed, with contact |
0 |
| Number of outputs, safety related, undelayed, semiconductors |
0 |
| Number of outputs, safety related, delayed, semiconductors |
0 |
| Number of outputs, signalling function, undelayed, semiconductors |
0 |
| Number of outputs, signalling function, delayed, semiconductors |
0 |
| With start input |
Yes |
| With muting function |
No |
| Voltage type for actuating |
AC/DC |
| Rated control supply voltage at DC |
24 V |
| Model |
Basic device |
| Type of electric connection |
Screw connection |
| Evaluation inputs |
One- and two-channel |
| Power consumption |
4 W |
| Terminal type |
Fixed |
| Fuses output |
External: 6 A slow blow or 10 A quick blow |
| Rated thermal current (Ith) |
Non switching: 6 A maximum in one current path |
| Continuous safety output current |
UL: B300, 5 A @ 250V AC, 24V AC, 6 A @ 24V DC, AC-15: 6 A @ 250V AC, DC-13: 3 A @ 24V DC |
| Wire size |
0.2 to 2.5 mm² |
| Electrical life cycle |
100000 (220V AC / 4 A / 880VA cosφ = 0.35), 500000 (220V AC / 1.7 A / 375VA cosφ = 0.6), 1000000 (30V DC / 2 A / 60 W), 2000000 (10V DC / 0.01 A / 0.1 W) |
| Number of outputs, signalling function, delayed, with contact |
0 |
| With feedback circuit |
Yes |
| Suitable for monitoring of magnetic switches |
Yes |
| Suitable for monitoring of proximity switches |
Yes |
| Suitable for monitoring of emergency-stop circuits |
Yes |
| Suitable for monitoring of optoelectronic protection equipment |
Yes |
| Suitable for monitoring of position switches |
Yes |
| Suitable for monitoring of tactile sensors |
Yes |
| Suitable for monitoring of valves |
Yes |
| Immediate safe dry No output |
2 |
| Impulse withstand voltage |
2500 V |
| Switching current, min |
10 mA @ 10V |
| Output utilization per IEC 60947-4-1, resistive |
DC-1: 6 A @ 24V DC |
| Utilization category |
UL: B300, 5 A/250V AC, 24V AC, 6 A/24V DC |
| Operating voltage range |
24V AC/DC, 0.85 to 1.1 x rated voltage 50 60 Hz |
| Output utilization per IEC 60947-5-1, inductive |
P300, DC-13: 3 A @ 24V DC, 6 A @ 24V DC @ 6 ops/min |
0.0 Average Rating Rated (0 Reviews)