140MX-C2E-C16 American Rockwell AB circuit breaker.

0 reviews

140MX-C2E-C16 American Rockwell AB circuit breaker.Low voltage products Model No: 140MX-C2E-C16.Motor Protection Circuit-Breaker.

Description

PRODUCT INFORMATION OF 140MX-C2E-C16 American Rockwell AB circuit breaker.

With integrated auxiliary switch No
With integrated under voltage release No
Rated short-circuit breaking capacity lcu at 400 V, AC 65 kA
Rated operation power at AC-3, 400 V 7.5 kW
Rated operation power at AC-3, 230 V 4 kW
Rated operating voltage 230 A
Type of control element Turn button
Overload release current setting 10 A
Type of electrical connection of main circuit Screw connection
Magnetic release current per IEC 208 A
Rated operational current (Ie) per IEC 16 A
Magnetic trip current 208 A
Short circuit current (Type 2 coordination), max-inv 50 kA @ 400V
Current range 10…16 A
Ultimate short circuit breaking capacity (Icu) per IEC 65 kA @ 400/415V
Rated service short circuit breaking capacity (Ics) per IEC 6 kA @ 500V
Hp rating, max 5 Hp @ 230V, 3-phase
Rated operating voltage, max 690V per IEC, SEV, VDE0660
Electrical life cycle (Ie max.) 100000 operations
Short circuit current for combination motor controller with 100-K contactor, max-inv 30 kA @ 480Y/277V, UL 508-Type F
Short circuit current for combination motor controller with 100-C contactor, max-inv 30 kA @ 480Y/277V, UL 508-Type F
Short circuit current for self-protected combination motor controller with 100-C contactor, max-inv 30 kA @ 480Y/277V, UL 508-Type E
Switching of standard motors per IEC 7.5 kW @ 400/415V, 3-phase
KW rating, max 7.5 kW @ 415V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC No back-up fuse required @ 230/240V
Short circuit current for group motor installation with 100-K contactor, max-inv 30 kA @ 600V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-K contactor, max-inv 30 kA @ 600V, UL 508-manual motor controller
Short circuit current for group motor installation with 100-C contactor, max-inv 30 kA @ 600V, UL 508-manual motor controller
Short circuit current for motor disconnect with 100-C contactor, max-inv 30 kA @ 480V, UL 508-manual motor controller
Rated thermal current 0.1…32 A @ 60 °C ambient temperature (Ith)-inv
Short circuit current for tap conductor protection, max 30 kA @ 480Y/277V per UL 508-manual motor controller
Short circuit current for combination motor controller, max 30 kA @ 480V/277V per UL 508-self-protected (Type E)
Fuse or circuit breaker per NEC, max 450 A, UL 508-manual motor controller
Fuse or circuit breaker rating per NEC, max 450 A, UL 508-manual motor controller with 100-C contactor
Short circuit current for group motor installation, max 30 kA @ 600V, UL 508-manual motor controller
Short circuit current for motor disconnect, max 30 kA @ 600V, UL 508-manual motor controller
Magnetic release current Fixed setting 13…14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %)
Number of poles 3
With thermal protection Yes
Phase failure sensitive Yes
Switch off technique Thermomagnetic
Switching frequency, max 25 ops/h
Trip class 10
Rated frequency 50/60 Hz
Rated supply current 0.1 A
Total power loss (Pv) for circuit breaker at rated load operating temperature-inv 6 W
Phase loss protection Differential release
Fuse or circuit breaker rating with 100-K contactor per NEC, max 450 A, UL 508-manual motor controller
Main circuits/overvoltage category 6kV/III @ rated impulse withstand voltage (Uimp)
Auxiliary circuits/overvoltage category-inv 6kV/III @ rated impulse withstand voltage (Uimp)