Schneider EZD160E3160N EZD160E 160A 3P3T plastic case circuit breaker  EZD molded case circuit breaker Model Number: EZD160E3100N The EZD160E3100N of the EZD series is a Class A Class 3 fixed molded case circuit breaker, which meets the requirements of IEC60947&GB14048 standards. The product has an isolation mark and the position of the operating handle can reliably indicate the position of the internal contacts. The maximum expected mechanical life of the product is 10,000 times and the electrical life is 5,000 times @440V&In. All terminal poles are equipped with overload and short circuit protection. Equipped with thermal magnetic release The rated current of the circuit breaker is 100A, and different electrical accessories and connection accessories can be selected according to different needs. The circuit breaker and auxiliary devices meet the requirements of 45°C and 95% relative humidity required by IEC60068-2-30, and the base plate can be selected according to actual needs Or the guide rail is installed in the switchgear and provides class II panel insulation from all internal circuits and the highest IP54 protection level. The materials used in the product are all non-polluting materials that meet the requirements of ISO14001 standards and can be recycled.

Description

PRODUCT INFORMATION OF SCHNEIDER EZD160E3100N EZD160E 160A 3P3T plastic case circuit breaker

 

main information

Product Series EZD
product type Breaker
product short name EZD160E
circuit breaker application Distribution protection
number of poles 3P
Description of protection pole 3D
Leakage current protection No leakage protection
Rated current [In] 100 A at 40 °C
Circuit breaker model E.
Network Type AC
Network frequency 50/60Hz
control type Handle
installation type Fixed
installation method Chassis mount
Connection method – top Front connection
Connection method – lower end Front connection
Rated insulation voltage [Ui] 690 V conforming to EN/IEC 60947-2
Rated impulse withstand voltage [Uimp] 6 kV conforming to EN/IEC 60947-2
Rated working voltage [Ue] 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity of EZD160E3100N 50 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA Icu at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA Icu at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
8 kA Icu at 500 V AC 50/60 Hz conforming to EN/ IEC 60947-2
use category of EZD160E3100N AC class
Use breaking capacity [Ics] 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2
13 kA at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2
13 kA at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
4 kA at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical life 10000 times
Electrical life 5000 cycles 440 V In conforming to EN/IEC 60947-2
Phase spacing 35 mm
Trip unit name TM-D
Trip unit type of EZD160E3100N Thermomagnetic
Release rating of EZD160E3100N 100 A at 40 °C
protection type of EZD160E3100N Overload protection (thermal protection)
short circuit protection (magnetic protection)
Long time delay current setting type Fixed
Long delay current setting value [Ir] 1 In
Instantaneous protection current setting type Fixed
Short circuit instantaneous protection 1000A
high of EZD160E3100N 165 mm
width of EZD160E3100N 105 mm
depth of EZD160E3100N 60 mm
Product Weight 1.3kg
model of EZD160E3100N EZD160
Standards compliant EN 60947-2
IEC 60947-2
pollution level 3 Conforming to IEC 60947-1
operating temperature -25…70°C
storage environment temperature -50…85 °C
Warranty 18 months