More items from this sellerView All

MT08N2 || Schneider Circuit Breaker 3P/4PMIC2.0A 5.0A 6.0A Fixed/Drawer

0 reviews

Schneider Circuit Breaker MT08N2 3P/4PMIC2.0A 5.0A 6.0A Fixed/Drawer  Schneider Frame Breakers Model Number: MT08N2

Description

PRODUCT INFORMATION OF SCHNEIDER Circuit Breaker MT08N2 3P/4PMIC2.0A 5.0A 6.0A Fixed/Drawer

 

main information

Product Series Masterpact
product type Ontology
Applications Protect
circuit breaker name Masterpact MT08N2
number of poles 3P
Network Type AC
Circuit breaker model N2
isolation function Applies to IEC 60947-2
use category Category B
Network frequency 50/60Hz
control type (Push) button
installation type Fixed
Rated current [In] 800 A at 40 °C
Rated insulation voltage [Ui] 1000 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp] 12 kV according to IEC 60947-2
Closure capacity [Icm] 105 kA 220/415 V AC at 50/60 Hz
105 kA 440 V AC at 50/60 Hz
105 kA 525 V AC at 50/60 Hz
105 kA 690 V AC at 50/60 Hz
Rated working voltage [Ue] 690 V AC 50/60 Hz conforming to IEC 60947-2
Transformer rating 800A
Breaking capacity 50 kA Icu at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Use breaking capacity [Ics] 50 kA at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life 12500 times without maintenance according to IEC 60947-2
25000 times with maintenance according to IEC 60947-2
Electrical life 10000 cycles at 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
10000 cycles at 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-23A: 10000 cycles at 440 V AC 50/60 Hz without maintenance conforming to IEC 60947 -2
AC-23A: 10000 cycles of 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-3: 6000 cycles of 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Phase spacing 115 mm
Rated short-time withstand current [Icw] 30 kA for 3 s conforming to IEC 60947-2
50 kA for 1 s conforming to IEC 60947-2
Maximum breaking time 25ms
Maximum closing response time 70ms
high 352 mm
width 422 mm
depth 297mm
Standards compliant IEC 60947-2
pollution level 4 Conforms to IEC 60664-1
operating temperature -25…70°C
storage environment temperature -40…85°C
Warranty 18 months

0.0 Average Rating Rated (0 Reviews)

Rated
0%
Rated
0%
Rated
0%
Rated
0%
Rated
0%

Be the first to review “MT08N2 || Schneider Circuit Breaker 3P/4PMIC2.0A 5.0A 6.0A Fixed/Drawer”

Your email address will not be published. Required fields are marked *

You have to login to add images.