PRODUCT INFORMATION OF Omron fiber optic amplifier sensor E3X-ZV11.
| Light source (wavelength) | Red, 4-element LED (625 nm) | ||||
|---|---|---|---|---|---|
| Power supply voltage | 12 to 24 VDC ±10%, ripple (p-p) 10% max. | ||||
| Power consumption | Normal mode: 720 mW max. (Power supply voltage 24 V: Current consumption 30 mA max. / Power supply voltage 12 V: Current consumption 60 mA max.) Eco function ON: 530 mW max. (Power supply voltage 24 V: Current consumption 22 mA max. / Power supply voltage 12 V: Current consumption 44 mA max.) |
Normal mode: 820 mW max. (Power supply voltage 24 V: Current consumption 35 mA max. / Power supply voltage 12 V: Current consumption 69 mA max.) Eco function ON: 600 mW max. (Power supply voltage 24 V: Current consumption 25 mA max. / Power supply voltage 12 V: Current consumption 50 mA m |
|||
| Control output | Load power supply voltage: 26.4 VDC, open collector output type (NPN or PNP output differs depending on the type.) Load current: 100 mA max. (Residual voltage: Load current less than 10 mA: 1V max., load current 10 to 100 mA: 2V max.) OFF current: 0.1 mA max. |
||||
| Indicators of Omron fiber optic amplifier sensor E3X-ZV11. | 7-segment displays (Threshold Level display: green, Incident Light Level display: red) Display direction: Switchable between normal and reversed. Smart Tuning Indicator (green) Standard models only: OUT indicator (orange) 2-channel models only: OUT1/2 indicator (orange), CH Indicator (green) |
||||
| Protection circuits | Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection |
||||
| Response time |
Super-highspeed mode (SHS) |
Operate or reset: 50 μs | Operate or reset: 100 μs | ||
| High-speed mode (HS) |
Operate or reset: 250 μs *1 | Operate or reset: 250 μs *2 | |||
| Standard mode (Stnd) |
Operate or reset: 1 ms *3 | Operate or reset: 1 ms *4 | |||
| Giga-power mode (GIGA) |
Operate or reset: 16 ms | Operate or reset: 16 ms | |||
| Sensitivity adjustment | Smart Tuning (2-point tuning, power tuning, percentage tuning (-99% to 99%), maximum sensitivity tuning, full auto tuning, position tuning) or manual adjustment |
||||
| Mutual interference prevention function | Emission cycle setting switching type (up to 4 units) |
Up to 2 units for E3X-MZV. Or, up to 2 units for E3X-ZV (the Unit Number Priority Mode), and 1 unit for E3X-MZV. |
|||
| Functions | DPC (Dynamic Power Control) |
Yes | |||
| ATC (Active Threshold Control) |
Yes | ||||
| Timer | Select from timer disabled, OFF-delay, ON-delay or one-shot timer: 1 to 9,999 ms |
||||
| Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||||
| Resetting settings | Select from initial reset (factory defaults) or user reset (saved settings). | ||||
| Eco mode | Select from OFF (digital display lit) and Eco ON (digital display not lit). | ||||
| Power tuning | Select from ON or OFF. | ||||
| Ambient illumination (Receiver side) |
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||||
| Ambient temperature range | Operating: -25°C to 55°C Storage: -30°C to 70°C (with no icing or condensation) |
||||
| Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above |
||||
| Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||
| Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
||||
| Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | ||||
| Weight (packed state/Sensor only) |
Approx. 95 g/ approx. 65 g |
Approx. 45 g/ approx. 20 g |
Approx. 100 g/ approx. 75 g |
Approx. 45 g/ approx. 20 g |
|
| Materials | Case | Polycarbonate (PC) | |||
| Cover | Polycarbonate (PC) | ||||
| Cable | PVC | ||||
| Accessories of Omron fiber optic amplifier sensor E3X-ZV11. | Instruction manual, Compliance sheet | ||||