Spot Schneider A9F18316 circuit breaker iC65N 3P C16A. air circuit breaker A9 miniature circuit breaker Model Number: iC65N-C16A/3P

Description

PRODUCT INFORMATION OF SCHNEIDER Spot A9F18316 circuit breaker iC65N 3P C16A. air circuit breaker

 

main information

Product Series of Spot Schneider A9F18316 Acti 9
Product Series Acti 9
product name IC65
product type Miniature Circuit Breaker
product short name IC65N
number of poles 3P
Applications Distribution Protection
Number of guard poles 3
Rated current [In] 16 A at 30 °C
Network Type AC
Trip unit type Thermomagnetic
Trip curve of Spot Schneider A9F18316 C
Breaking capacity 36 kA Icu at 12…133 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898 -1
use category AC class conforms to IEC 60947-2
isolation function Applies to IEC 60947-2
Network frequency 50/60Hz
Rated working voltage [Ue] 400 V AC 50/60 Hz
Magnetic trip limit 5…10 x In
current limiting level 3 Conforming to IEC 60898-1
Rated insulation voltage [Ui] 500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947-2
Contact position indication Have
control type of Spot Schneider A9F18316 Handle
local signal indication On/off indicator
installation type Locking clip lock
installation method DIN rail mounting
Width (multiples of 9mm) 6
high of Spot Schneider A9F18316 94 mm
depth of Spot Schneider A9F18316 78.5mm
Product Weight 316g
Mechanical life 20000 times
Electrical life 10000 times
Wiring capacity Tunnel terminal top or bottom 1…25 mm² Solid wire without wire terminal
Tunnel terminal top or bottom 1…16 mm² flexible wire (optional) with or without wire terminal
Stripping length 14 mm power return:
Tightening torque 2.5 Nm power circuit:
Leakage current protection (Required) additional assembly
Standards compliant IEC 60898-1
GB 10963.1
certified product CCC
CCS
CE
IP protection class IP20 conforming to IEC 60529
pollution level 3 Conforming to IEC 60947-2
Moisture resistance 2 Conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
operating temperature -35…70°C
storage environment temperature -40…85°C
Warranty of Spot Schneider A9F18316 18 months

0.0 Average Rating Rated (0 Reviews)

Rated
0%
Rated
0%
Rated
0%
Rated
0%
Rated
0%

Be the first to review “Spot Schneider A9F18316 circuit breaker iC65N 3P C16A. air circuit breaker”

Your email address will not be published. Required fields are marked *

You have to login to add images.