Description
PRODUCT INFORMATION OF SCHNEIDER TM258LF42DT PLC, M258 series PLC programmable controller spot
| Range of product | Modicon M258 |
|---|---|
| Product or component type | Logic controller |
| Product specific application | – |
| Discrete I/O number | 42 |
| discrete output number | 12 output 4 fast output |
| discrete input number | 10 for fast input 12 for input 4 for regular input |
| discrete input logic | Sink for fast input Sink for regular input Source for input |
| Discrete input voltage | 24 V |
| Discrete input voltage type | DC |
| voltage state 1 guaranteed | >= 15 V for fast input >= 15 V for fast output >= 15 V for regular input |
| voltage state 0 guaranteed | <= 5 V for fast input <= 5 V for fast output <= 5 V for regular input |
| discrete input current | 4 mA for fast input 4 mA for regular input |
| input impedance | 6 kOhm for fast input 6 kOhm for regular input |
| configurable filtering time | 0 ms for fast input/regular input and fast output 1.5 ms for fast input/regular input and fast output 12 ms for fast input/regular input and fast output 4 ms for fast input/regular input and fast output |
| anti bounce filtering | 2 µs…4 ms configurable fast input/regular input and fast output |
| maximum cable distance between devices | <30 m for fast input <30 m for fast output <30 m for regular input |
| isolation between channels and internal logic | 500 Vrms AC |
| isolation between channels | None |
| Discrete output logic | Source |
| discrete output voltage | 24 V DC |
| Output voltage limits | 19.2…28.8 V |
| discrete output current | 4 mA for fast output |
| [Us] rated supply voltage | 24 V DC for embedded expert modules power 24 V DC for I/O power segment 24 V DC for main supply |
| Supply voltage limits | 20.4…28.8 V |
| [In] rated current | 0.04 A for embedded expert modules power 10 A for I/O power segment 0.26 A for main supply |
| peak current | 100 kA (duration = <= 70 s) for main supply 25 kA (duration = <= 500 s) for I/O power segment 50 kA (duration = <= 150 s) for embedded expert modules power 1.2 A (duration = > 70 s) for main supply |
| Power consumption in W | 13.03 W |
| memory description | Flash 128 MB Internal RAM 64 MB |
| realtime clock | Without any user calibration clock, clock drift < 30 s/month at 25 °C With user calibration clock, clock drift <= 6 s/month |
| data backed up | Variables of type retain and retain persistent CR2477M Renata, 1.5 years autonomy |
| integrated connection type | 1 isolated serial link with female RJ45 connectorModbus with master/slave RTU/ASCII or character mode ASCII, physical interface: RS232/RS485, transmission rate: 300…115200 bps 1 isolated serial link with female RJ45 connectorEthernet Modbus TCP/IP with slave, physical interface: 10BASE-T/100BASE-TX 1 isolated serial link with mini B USB connector, transmission rate: 480 Mbit/s 1 isolated serial link with USB type A connector, transmission rate: 480 Mbit/s 1 CANopen with male SUB-D 9 connectorCANopen with master |
| transmission rate | 125 kbit/s for bus length of 500 m for CANopen 250 kbit/s for bus length of 250 m for CANopen 50 kbit/s for bus length of 1000 m for CANopen 500 kbit/s for bus length of 100 m for CANopen 10 kbit/s for bus length of 5000 m for CANopen 1000 kbit/s for bus length of 4 m for CANopen 20 kbit/s for bus length of 2500 m for CANopen 800 kbit/s for bus length of 25 m for CANopen |
| counting input number | 8 counting input(s) at 200 kHz |
| local signalling | 1 LED per channel for I/O state 1 LED for CAN0 STS 1 LED for MBS COM 1 LED green/red for APP0 1 LED green/red for APP1 1 LED green/red for Eth NS (Ethernet network status) 1 LED green/red for Eth ST (Ethernet status) 1 LED green/red for RUN/MS (module status) 1 LED green/red for USB host 1 LED green/yellow for Eth LA (Ethernet activity) 1 LED red for BATT (battery status) |
| Marking of TM258LF42DT PLC | CE |
| Mounting support | Symmetrical DIN rail |
| Width of TM258LF42DT PLC | 175 mm |
| Height of TM258LF42DT PLC | 99 mm |
| Depth of TM258LF42DT PLC | 85 mm |
| Product weight | 0.55 kg |
| Standards of TM258LF42DT PLC | UL 508 CSA C22.2 No 142 IEC 61131-2 CSA C22.2 No 213 |
| Product certifications | GOST-R cULus C-Tick CSA |
| ambient air temperature for operation | 0…55 °C without derating (horizontal installation) 0…60 °C with derating factor (horizontal installation) 0…50 °C (vertical installation) |
| Ambient air temperature for storage | -25…70 °C |
| relative humidity | 5…95 % without condensation |
| IP degree of protection | IP20 conforming to IEC 61131-2 |
| pollution degree of TM258LF42DT PLC | 2 conforming to IEC 60664 |
| Operating altitude of TM258LF42DT PLC | 0…2000 m |
| Storage altitude of TM258LF42DT PLC | 0…3000 m |
| vibration resistance of TM258LF42DT PLC | 1 gn at 8.4…150 Hz on DIN rail 3.5 mm at 5…8.4 Hz on DIN rail |
| shock resistance | 15 gn for 11 ms |
| resistance to electrostatic discharge | 4 kV on contact conforming to EN/IEC 61000-4-2 8 kV in air conforming to EN/IEC 61000-4-2 |
| resistance to electromagnetic fields | 1 V/m 2…2.7 GHz conforming to EN/IEC 61000-4-3 10 V/m 80…2000 MHz conforming to EN/IEC 61000-4-3 |
| resistance to fast transients | 1 kV (I/O) conforming to EN/IEC 61000-4-4 1 kV (shielded cable) conforming to EN/IEC 61000-4-4 2 kV (power lines) conforming to EN/IEC 61000-4-4 |
| surge withstand of TM258LF42DT PLC | 0.5 kV differential mode conforming to EN/IEC 61000-4-5 1 kV common mode conforming to EN/IEC 61000-4-5 |
| Disturbance radiated/conducted | CISPR 11 |
| Warranty of TM258LF42DT PLC | 18 months |


0.0 Average Rating Rated (0 Reviews)