Main

Range Masterpact
Product name MasterPact MTZ2
Device short name MTZ2 40 H3
Product or component type Circuit breaker
Device application Protection
Poles description 4P
Neutral position Left
Network type AC
Network frequency 50/60 Hz
Breaking capacity code H3
suitability for isolation Yes conforming to IEC 60947-2
selectivity category Category B
Control type Push-button
Mounting mode Drawout
Mounting support Rails
Base plate
[In] rated current 4000 A at 40 °C
[Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
[Icm] rated short-circuit making capacity 330 kA 220/415 V AC at 50/60 Hz
330 kA 440 V AC at 50/60 Hz
286 kA 500/525 V AC at 50/60 Hz
220 kA 660/690 V AC at 50/60 Hz
[Ue] rated operational voltage 440 V AC 50/60 Hz conforming to IEC 60947-2
Circuit breaker CT rating 4000 A
performance level 150 kA Icu at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
150 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
130 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 150 kA at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
150 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
130 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
100 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
mechanical durability 20000 cycles with periodic preventive maintenance conforming to IEC 60947-2
electrical durability 1250 cycles 440 V AC 50/60 Hz conforming to IEC 60947-2
1250 cycles 690 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch 150 mm
[Icw] rated short-time withstand current 66 kA 0.5 s conforming to IEC 60947-2
66 kA 1 s conforming to IEC 60947-2
66 kA 3 s conforming to IEC 60947-2
Integral instant protection 135…165 kA
Maximum breaking time 25 ms
Maximum closing response time 70 ms
height of MTZ2 40H3 Schneider air circuit breaker Drawout circuit breaker without chassis: 300 mm
Drawout circuit breaker with chassis: 439 mm
width of MTZ2 40H3 Schneider air circuit breaker Drawout circuit breaker without chassis: 493 mm
Drawout circuit breaker with chassis: 556 mm
depth of MTZ2 40H3 Schneider air circuit breaker Drawout circuit breaker without chassis: 300 mm
Drawout circuit breaker with chassis: 403 mm
Standards IEC 60947-2
IEC 60364-8-1
Product certifications ASEFA
pollution degree 3 conforming to IEC 60947-1
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C